有码中文av无码中文_国产亚洲AV综合人人澡_亚洲 小说 欧美_被征服到高潮的娇妻精品_姪女太小进不去视频在线观看_欧美日韩第一页免费观看_国产精品久久一区二区五区_国产草莓视频无码a在线观看_丰满熟女内射_色又爽又黄18禁美女裸身网站

月恒儀器儀表

Yueheng Instrument & Apparatus

PRODUCTS

Yueheng Instrument & Apparatus

PRODUCTS

○  Metal tube float flowmeter

○  Micro metal tube float flowmeter

○  All stainless steel metal tube float flowmeter

○  Magnetic filter

○  Imported series glass rotameter

○  Domestic series glass rotameter

○  Plastic rotameter

○  Panel flowmeter

○  Pipeline flowmeter

Vortex Flowmeter

 

Summary
Vortex flowmeter is a new type of flowmeter with international advanced level, which is developed based on the principle of Karman Vortex Street. It is suitable for measuring superheated steam, saturated steam, general gas and liquid.
Product features
◆ Simple structure, no moving wear parts.
◆ High measurement accuracy and reliability, without on-site commissioning.
◆ It can transmit flow signals at a long distance, and can be connected with computers to realize centralized management.
◆ The amplification board adopts a unique design, which is universal for gas and liquid.
Technical indicators
◆ Accuracy class: 1.0 1.5
◆ Nominal pressure: 1.6MPa, 2.5MPa, 4.0MPa and above
◆ Temperature of measured medium: - 40 ℃~350 ℃
◆ Pressure loss: resistance coefficient cd ≤ 2.4
◆ Power supply: 12~24VDC
◆ Explosion-proof grade: la Ⅱ CT6 (intrinsically safe explosion-proof)
◆ Output signal: voltage pulse low level ≤ 1V high level ≥ 6V, standard current signal 4~20mA
◆ Accuracy class: 1.0 1.5
◆ Nominal pressure: 1.6MPa, 2.5MPa, 4.0MPa and above
◆ Temperature of measured medium: - 40 ℃~350 ℃
◆ Pressure loss: resistance coefficient cd ≤ 2.4
◆ Power supply: 12~24VDC
◆ Explosion-proof grade: la Ⅱ CT6 (intrinsically safe explosion-proof)
◆ Output signal: voltage pulse low level ≤ 1V high level ≥ 6V, standard current signal 4~20mA
Flow range


Sensor diameter
(mm)
Liquid (calibration medium: normal temperature water) Gas (calibration medium: air at 20 ℃ 101325Pa)
Standard Extensibility
15 0.8~6 0.5~8 6~40 5~50
20 1~8 0.6~12 8~50 6~60
25 1.5~12 0.8~16 10~80 8~120
40 2.5~30 2~40 250~200 20~300
50 3~50 2.5~60 30~300 25~500
65 5~80 4~100 50~500 40~800
80 8~120 6~160 80~800 60~120
100 12~200 8~250 120~1200 100~2000
125 20~300 12~400 160~1600 150~3000
150 30~400 18~160 250~2500 200~4000
200 50~800 30~1200 400~4000 350~8000
250 80~1200 40~1600 600~6000 500~12000
300 100~1600 60~2500 1000~10000 600~16000
400 200~3000 120~5000 1600~16000 1000~25000
500 300~5000 200~8000 2500~25000 1600~40000
600 500~8000 300~10000 4000~40000 2500~60000

Overall dimension

Caliber L1 L2 D1 D2 H D3 N
20 65 95 125 100 460 13 4
25 65 95 125 100 460 13 4
40 75 109 145 110 470 13 4
50 75 109 160 125 481 17 4
65 75 117 180 145 497 17 6
80 80 122 195 160 510 17 6
100 90 132 230 190 544 17 8
125 100 146 245 210 564 17 8
150 120 170 280 240 594 21 8
200 150 200 335 295 646 21 12
250 160 214 405 355 708 21 12
300 170 224 460 410 760 21 12

Instrument installation

The sensor shall be installed on the horizontal, vertical, inclined (liquid flow from bottom to top) pipeline with the same diameter. The upstream and downstream of the sensor shall be equipped with a certain length of straight pipe section, which shall meet the requirements of 15~20D for the front straight pipe section and 5~10D for the rear straight pipe section. The pipeline near the liquid sensor shall be filled with the measured liquid. The sensor shall not be installed on the pipeline with strong mechanical vibration. The inner diameter of the straight pipe section shall be consistent with the diameter of the sensor as much as possible. If it cannot be consistent, the pipe slightly larger than the diameter of the sensor shall be used, and the error shall be ≤ 3%, not more than 5mm. If the measured medium contains many impurities, a filter shall be installed beyond the length required by the straight pipe section upstream of the sensor. The sensor shall not be installed in places with strong electromagnetic interference, small space and inconvenient maintenance.

Summary

On-site display vortex flowmeter has the characteristics of miniaturization, micro-power consumption, intelligence, etc., realizing the measurement, display and integration of flow parameters. The field display instrument is used in an environment where the power supply is not convenient: the instrument is designed with an ultra-low power consumption chip, which is convenient to operate, and is at the leading level among similar domestic products.

Model LUGB-X liquid crystal type
Double-row LCD, 8-digit digital display
User can set small signal cutoff
4~20mA two-wire current output (equipped according to user's order requirements)
Online temperature compensation, manual fixed value density compensation
12V~24V or 3.6V lithium battery power supply

Flow range of plug-in vortex flowmeter

The plug-in vortex flow sensor is applicable to the measurement of superheated steam, saturated steam, general gas and liquid above DN200 pipe; It can be displayed on site or output remotely; Its installation is convenient and the price is cheap; Accuracy: ± 1.5%, ± 2.5%.

Drift diameter DNmm 200 250 300 350 400 450 500

liquid m³/h

55~570 88~885 125~1275 170~1735 225~2265 286~2670 350~3540

Gas m³/h

560~4530 880~7070 1270~10180 1730~13860 2260~18100 2860~22905 3530~28275

Drift diameter DNmm

600 700 800 900 1000 1100 1200

liquid m³/h

505~5090 690~6930 900~9050 1145~11450 1410~14140 1710~17110 2035~20360

Gas m³/h

5080~40715 6925~55420 9045~72380 11450~91605 14135~113095 17100~136840 20235~162850

Drift diameter DNmm

1300 1400 1500 1600 1800 2000  

liquid m³/h

2385~23895 2770~27710 3170~31800 3610~36200 4580~45850 5650~56550  

Gas m³/h

23890~191125 27705~221160 31700~254455 36105~289510 45750~366410 56545~452365  

HOME  |   ABOUT US  |   PRODUCTS  |   HONORS  |   NEWS  |   FACTORY  |   ORDER  |   JOBS  |   CONTACT  |   中文版

Copyright(C)2022, Changzhou Yueheng Instrument & Apparatus Co., Ltd. All Rights Reserved. Supported by Toocle Copyright Notice 備案序號(hào):蘇ICP備09011979號(hào)-2