Summary:
LZ series metal tube float flowmeter has simple structure, reliable operation, high accuracy and wide application range. It is widely used in the measurement and control of liquid and gas flow in the fields of national defense, chemical industry, petroleum, metallurgy, electric power, environmental protection, medicine, etc.
The electrically remote metal tube float flowmeter produced by our company abandons the contact transmission mode of connecting rod transmission, and adopts the independently developed non-contact intelligent transmitter with MSP as the core CPU, which greatly improves the reliability, stability and accuracy of the instrument.
◆ Material: 304SS, 316SS, 316LSS, 304SS lining F46, titanium, HC and other materials
◆ Connection: flange connection, HG20592-20615-7-2000 standard, or GB, ANSl, DIN, JIS and other standards (proposed by the user) can be threaded connection, hose connection, sanitary clamp connection, or customized according to the standards or specifications required by the user.
◆ Type: vertical, horizontal, bottom in and side out, side in and side out, etc.
◆ Power supply:+24VDC, AC220V, high-energy dry battery power supply
◆ Output: two-wire 4-20mA, (1-5V) output, upper and lower limit switch value alarm output. hart protocol
◆ Explosion-proof: intrinsic safety ExibIICT3~T6 certificate number is GYB101238 Explosion-proof ExdIIBT3~T6 certificate number is GYB101359X
◆ Indicator housing material: aluminum alloy, explosion-proof aluminum alloy, 304SS, 316L
Technical indicators:
◆ Measurement range: water (2.5~150000) L/h; Air (0.07~2000) m3/h (at 0.101325 Mpa, 20 ℃).
◆ Accuracy level: 1.5 and 2.5 (PTFE).
◆ Range ratio: 10:1 (or special 5:1).
◆ Nominal pressure: DN15~50 ≤ 4.0MPa; DN65~150 ≤1.6MPa。
◆ Medium temperature: - 80 ℃~200 ℃ (lined with F46 flowmeter 0 ℃~80 ℃). Liquid medium viscosity: DN15<5mPa • s;
DN25~150≤250mPa•s。
◆ Output: 4-20mA two-wire system
Pure resistive load < 680 Ω
Linearity < 0.5%
Temperature effect < 5MA/K
◆ Ambient temperature: - 25 ℃~55 ℃.
◆ Total height: DN15~DN150 (generally 250mm).
See Table 1 for flow range
Caliber |
Water(L/h)20℃ 0.101325MPa |
Air(m3/h)20℃ 0.101325MPa |
Pressure |
Drift diameter |
float(CrNi Hc) |
float(PTFE Ti) |
float(CrNi Hc) |
float(PTFE Ti) |
4.0MPa |
15 |
1.6-16 |
|
0.05-0.5 |
0.075-0.75 |
2.5-25 |
2.5-25 |
0.075-0.75 |
0.12-1.2 |
4.0-40 |
4.0-40 |
0.12-1.2 |
0.18-1.8 |
6.0-60 |
6.0-60 |
0.18-1.8 |
0.30-3.0 |
10-100 |
10-100 |
0.30-3.0 |
0.45-4.5 |
16-160 |
16-160 |
0.45-4.5 |
0.75-7.5 |
25-250 |
25-250 |
0.75-7.5 |
1.2-12 |
40-400 |
40-400 |
1.2-12 |
1.8-18 |
60-600 |
60-600 |
1.8-18 |
0.75-7.5 |
20 |
40-400 |
25-250 |
0.75-7.5 |
1.2-12 |
60-600 |
40-400 |
1.2-12 |
1.8-18 |
100-1000 |
60-600 |
1.8-18 |
3.0-30 |
25 |
100-1000 |
100-1000 |
3.0-30 |
5.0-50 |
160-1600 |
120-1200 |
5.0-50 |
7.5-75 |
250-2500 |
160-1600 |
7.5-75 |
|
400-4000 |
250-2500 |
|
3.0-30 |
32 |
160-1600 |
120-1200 |
5.0-50 |
5.0-50 |
250-2500 |
160-1600 |
7.5-75 |
7.5-75 |
400-4000 |
250-2500 |
12-120 |
|
600-6000 |
|
|
3.0-30 |
40 |
400-4000 |
100-1000 |
7.5-75 |
5.0-50 |
600-6000 |
160-1600 |
12-120 |
7.5-75 |
1000-10000 |
250-2500 |
18-180 |
12-120 |
50 |
600-6000 |
400-4000 |
12-120 |
18-180 |
1000-10000 |
600-6000 |
18-180 |
30-300 |
1600-16000 |
1000-10000 |
30-300 |
|
2000-20000 |
1200-12000 |
37-370 |
18-180 |
1.6MPa |
65 |
1200-12000 |
600-6000 |
18-180 |
30-300 |
1600-16000 |
1000-10000 |
30-300 |
37-370 |
2500-25000 |
1200-12000 |
37-370 |
50-500 |
80 |
2500-25000 |
1600-16000 |
37-370 |
75-750 |
4000-40000 |
2500-25000 |
75-750 |
120-1200 |
100 |
4000-40000 |
2500-25000 |
120-1200 |
|
6000-60000 |
4000-40000 |
180-1800 |
120-1200 |
125 |
8000-80000 |
4000-40000 |
120-1200 |
|
10000-100000 |
6000-60000 |
180-1800 |
180-1800 |
150 |
12000-120000 |
6000-60000 |
200-2000 |
|
15000-150000 |
8000-80000 |
|
|
Product selection
1. Model selection
2. Description
A |
B |
C |
D |
E |
Drift diameter |
Structural form (medium flow direction)
|
Measuring tube material
|
Attachment structure
|
Converter function combination
|
DN
15
20
25
32
40
50
65
80
100
125
150 |
Y10 - lower in and upper out
Y20L left in right out (horizontal)
Y20R - right in and left out (horizontal)
Y30 - in and out on the same side
Y40 - inlet and outlet at opposite side
Y50 bottom in side out
Y60 side in and out
|
RR1-304SS
RR0-316SS
RRL-316L
RP-304+PTFE
Ti-pure titanium alloy
HC Hastelloy
|
Z-damping type
T-jacket type
F - Anti-corrosion type
G-high temperature type
Y-high pressure type
|
ESK-24V DC power supply, two-wire system 4-20mA standard current signal output intrinsic safety explosion-proof (Exib Ⅱ CT3-T6)
K1-24V DC power supply with upper limit alarm point output
K2-24V DC power supply with lower limit alarm point output
K12-24V DC power supply with upper and lower limit alarm point output
JSB - lithium battery power supply, LCD display instantaneous and cumulative flow
JSC-2220V AC power supply, LCD display instantaneous and cumulative flow
JSD-220V AC power supply, LCD display instantaneous and cumulative flow, 4-20mA standard current signal output
JSE-24V DC power supply, LCD display instantaneous and cumulative flow, 4-20mA standard current signal output
Exd-flameproof, 24V DC power supply, LCD display of instantaneous and cumulative flow, 4-20mA standard current signal output
HART - HART communication protocol
|
3. Flow direction diagram
4. Meter head type and model